DS DS/EN 61158-4-12
DS DSEN 61158-4-12 2008-APR-14 ndustral communcaton networks - Feldbus specfcatons -- Part 4-12 Data-lnk layer protocol specfcaton - Type 12 elements
DS DSEN 61158-4-12 2008-APR-14 ndustral communcaton networks - Feldbus specfcatons -- Part 4-12 Data-lnk layer protocol specfcaton - Type 12 elements
1.1 General
The data-link layer provides basic time-critical messaging communications between devices in an automation environment.
This protocol provides communication opportunities to all participating data-link entities
a) in a synchronously-starting cyclic manner, and
b) in a cyclic or acyclic asynchronous manner, as requested each cycle by each of those data-link entities.
Thus this protocol can be characterized as one which provides cyclic and acyclic access asynchronously but with a synchronous restart of each cycle.
1.2 Specifications
This standard specifies
a) procedures for the transfer of data and control information from one data-link user entity to one or more user entity;
b) the structure of the DLPDUs used for the transfer of data and control information by the protocol of this standard, and their representation as physical interface data units.
1.3 Procedures
The procedures are defined in terms of
a) the interactions between DL-entities (DLEs) through the exchange of DLPDUs;
b) the interactions between a DL-service (DLS) provider and a DLS-user in the same system through the exchange of DLS primitives;
c) the interactions between a DLS-provider and the MAC services of ISO/IEC 8802-3.